Wrist Straps - 3 sets
RCF-A1013EN
The Patient Wrist Straps are designed to attach a patient’s arms to the ACC for ease of transporting the patient and the ACC.
The Patient Interface Pad (PIP) is a user-replaceable, snap-on, single patient use component that provides the interface between the piston and the patient’s chest.
The Patient Wrist Straps are designed to attach a patient’s arms to the ACC for ease of transporting the patient and the ACC.
The Patient Wrist Straps are designed to attach a patient’s arms to the ACC for ease of transporting the patient and the ACC.
The Torso Stabilization Strap is designed to help ensure the ACC remains appropriately positioned once compressions have started. The Torso Stabilization Strap is placed behind the patient’s neck and connected to the Frame by pushing the Torso Stabilization Strap clips into the Frame's Torso Stabilization Strap connectors until they click into place.
The Battery Pack provides a replaceable primary power source for the Compression Module.
The external AC Adapter Power Module/Charger provides external power to run the ACC and charge the installed Battery Pack.
The Battery Pack Charging Station is an optional accessory that charges up to two Battery Packs simultaneously.
The ACC Storage Carrying Case is a structured case designed for backpack portability containing a custom foam insert that perfectly contours the ACC components, accessories, and spares enabling easy access and repacking.
An optional accessory, this uniquely designed ACC Tactical Case is encircled by the Frame and the Backboard of the ACC device. The result is a carrying case that is lightweight and takes up very little room. Visibility and access simplify basic tasks of routine maintenance.
The base for the ACC system is a Backboard with self-locking latches that provides an interface that the Frame attaches to. It is placed under the patient and has attachment points to which the Frame latches.
The Frame is used to maintain the Compression Module’s position over the patient. It attaches to the Backboard when the Frame latches are aligned over the Backboard pins and pushed down until the latches snap into place. The latches may be clicked into place one at a time or simultaneously.
Preventative Maintenance is recommended at an interval of every 18 months, or every 200 hours of operation, whichever comes first. It provides a simple and essential solution for users who need to maintain the unit’s performance over time.
The Premium Service Plan is a comprehensive service plan for total equipment care offering warranty and post-warranty benefits and coverage. It includes maximum coverage for the ACC device including repairs for the customer who needs to maintain the ACC device’s performance and uptime.
A USB port is located on the bottom of the ACC’s Compression Module. It may be connected to a personal computer using a standard USB Cable (USB-A to Mini-B). Downloading ACC event reporting is possible when used in conjunction with data retrieval utility software available at www.defibtech.com.
Defibtech products are available through authorized domestic and international distributors. Please fill out the form and we will help you select a distributor that best meets your needs.